3D L.A.S.A.R. Posture
Devices with correct static alignment have a positive effect on users’ posture and mobility: Malpositions are minimised, the body is relieved and users find it easier to maintain their balance.
Devices with correct static alignment have a positive effect on users’ posture and mobility: Malpositions are minimised, the body is relieved and users find it easier to maintain their balance.
The 3D L.A.S.A.R. Posture supports technicians in providing optimal prosthetic and orthotic alignments as well as in checking body posture. Our latest new developments for this proven product, which is highly valued in everyday work thanks to its numerous advantages, make working with the 3D L.A.S.A.R. Posture even easier and more comfortable. We placed particular focus on simplifying the documentation process as well as expanding the measurement function.
With the new 3D L.A.S.A.R. Posture, cameras take a live recording of the patient standing on the measuring plate and transmit the image to a tablet PC. The measured forces are represented as lines on the tablet’s display, which are positioned with millimetre accuracy over the patient’s image.
Voltage | 1x230 V |
Frequency | 50-60 Hz |
Weight | 20 lbs |
All benefits at a glance
3D L.A.S.A.R. Posture
It is possible to verify the effect of stabilizing a joint using ground reaction forces during the measuring process.
Adjusting the plantar flexion under a load makes fine adjustments to the device especially quick and precise.
Easy to transport
Modern und functional design
Automatic and comprehensive documentation of fittings
Simplifies communication with paying parties
Tablet with integrated help function
Synchronous measurement and visualization of the force path along both legs including load distribution display and measurement of the vertical forces as with L.A.S.A.R. Posture
Extensive tutorials, help functions and integrated recommendations for prosthetic alignments
Easy camera view switching means device wearer doesn’t need to be repositioned
Illustration of the vertical and horizontal forces displays the actual load
Screenshot function for rapid capture and analysis of the measuring situation
Comprehensive patient database with fitting progression, comparison view and PDF creation feature
Areas of application
Static alignment or verification of body posture in:
- Lower limb prosthetics
- Custom lower limb orthotics
- Orthopaedic foot care
- Incorrect posture of pelvis and legs
- Leg length discrepancy
- Physiotherapy
- Rehabilitation
Prosthetics
- Lower leg prosthetics
- Upper leg prosthetics
- Hip disarticulation prosthetics
Orthotics
- Orthopaedic inserts and foot care
- Ankle foot orthoses
- Knee ankle foot orthoses
- Hip knee ankle foot orthoses
Product information
Voltage | 1x230 V |
Frequency | 50-60 Hz |
Weight | 20 lbs |